The CXDI-31 is the world’s first
portable DR system. With a
compact and lightweight design,
the Canon CXDI-31 can be freely
positioned to capture images at
angles difficult to get with
fixed devices such as lateral
and axial imaging of shoulders,
skull, neck and extremities. The
high-resolution CXDI-31 is
perfect for pediatric and
orthopedic applications.

Download Brochure
Features
As the world’s first
portable digital radiography
detector, the CXDI-31
extends the benefits of DR
to a wide range of
applications, including
neonatal and trauma
radiography.
• Compact and
Lightweight
The compact size of the
CXDI-31 provides image
capture from virtually
any angle or position.
Yet the detector weighs
only 6.2 pounds!
• Enhanced
Productivity
The technologist selects
the necessary views to
complete the requested
exam or the requested
views are automatically
selected through
communication between
the DICOM worklist and
the RIS.
• Immediate Results
An on-screen preview
image is available just
3-5 seconds after
exposure. Sequential
images can be acquired
in as little as 6
seconds.
• Seamless Network
Integration
Ethernet 10/100 Base T
connectivity with DICOM
3.0 compatibility
enables seamless data
transfer to any DICOM
hard copy output device,
PACS, or HIS/RIS for
efficient printing,
archiving, and remote
viewing of Images. The
system complies with IHE
(Integrating the
Healthcare Enterprise)
standards for
interoperability to
ensure easy, effective
integration with the
hospital network.
Specifications
|
Detector |
|
|
|
Detector
|
LANMIT 2,
Amorphous
Silicon and
Scintillator |
|
|
Scintillator |
Gadolinium
Oxysulfide (GOS) |
|
|
Pixel Pitch |
100 x 100
microns |
|
|
Pixels |
2,256 x 2,878
(6.4 million) |
|
|
Imaging Area |
9” x 11” (23 cm
x 29 cm) |
|
|
|
Image
Acquisition and
Processing |
|
|
|
A/D |
14 bit |
|
|
Grayscale |
12 bit (4,096
gradations) |
|
|
Preview Image |
3-5 seconds |
|
|
Refresh Cycle |
6-10 seconds |
|
|
|
Data
Output and
Network
Connection |
|
|
|
Network |
Ethernet 10/100
Base T, RJ45
standard,
wireless
optional |
|
|
Data Output
|
DICOM 3.0
compliant, Print
Management
Service Class (SCU),
Storage Service
Class (SCU), and
others |
|
|
|
Electrical and
Environmental |
|
|
|
Voltage |
100V, 120V,
230/240V
(50/60Hz) |
|
|
Power
Consumption |
300VA maximum
(Detector unit
only) |
|
|
Operating
Environment
|
(Detector unit
only)
50-95°F
(10-35°C),
30-75% RH
(non-condensing) |
|
|
|
Physical
Characteristics |
|
|
|
Dimensions WxLxH |
12.8” x 12.9” x
0.8” (324 x 327
x 20 mm)
(Detector unit
only) |
|
|
Weight |
6.2 lbs. (2.8
kg) |
|